Splitter ya Fiber Optic ya G657A2 Kwa Sensorer za macho za LC, Lc Lc St St Coupler
Aina ya Kiunganishi: | SC, FC, LC, ST | Uso wa mwisho wa Ferrule: | PC, UPC, APC |
---|---|---|---|
Aina ya nyuzi: | G652D G657A1 G657A2 | Njia ya nyuzi: | Singlmode |
Kifurushi: | Chuma Tube, ABS | Muundo: | 1 × 32 2 × 32 |
Fibre Optic Splitter kwa Sensorer za Optical za GIP
Maelezo:
Splitter ya macho ya PLC ni kipengee cha macho kidogo kinachotumia mbinu za photolithographic kuunda mwongozo wa macho kwenye substrate ya kati au semiconductor kwa kutambua kazi ya usambazaji wa tawi.
Splitters za nyuzi zinapatikana na 1 × 2, 1 × 3, 1 × 4, 1 × 5, 1 × 6, 1 × 8, 1 × 12, 1 × 16, 1 × 18, 1 × 32 na 1 × 64 mazungumzo na mode moja au multimode fiber na tunatoa viunganisho vyote vya aina ya pre-connectorized kama SC, FC, ST, LC na E2000 nk.
Makala:
Kupoteza chini ya kuingizwa
Upungufu wa chini wa ubaguzi
Hasara ya Kurudi Juu
Hiari ya Kugawanyika 20/80, 40/60… (50/50 kama chaguo-msingi.)
Compact kwa maeneo madogo ya matumizi kama vile kufungwa au trays za splice
Upana wa Joto la Uendeshaji na Wavelength
Mazingira bora na Utulivu wa Mitambo
Waliohitimu Chini ya Telcordia GR-1221 na GR-1209
Ukubwa wa bomba la chuma
Maombi:
FTTX (FTTP, FTTH, FTTN, FTTC)
Mitandao ya Optical Optical (PON)
Mitandao ya Eneo la Mitaa (LAN)
Mifumo ya CATV
Kuongeza, Mfumo wa Ufuatiliaji
Vifaa vya Mtihani
Habari ya Agizo
Kwa Splitters za FBT, Fiberstore hutoa safu nzima ya aina hii iliyoboreshwa kwa maalum
Maelezo:
Jedwali 1 - 1 × N PLC Splitter ya nyuzi
Vigezo | 1 × 2 | 1 × 4 | 1 × 8 | 1 × 16 | 1 × 32 | 1 × 64 |
Uendeshaji wa Wavelength (nm) | 1260 hadi 1650 | |||||
Aina ya nyuzi | G657A au mteja ameainishwa | |||||
Kupoteza Uingizaji (dB) (Daraja la P / S) | 3.8 / 4.0 | 7.1 / 7.3 | 10.2 / 10.5 | 13.5 / 13.7 | 16.5 / 16.9 | 20.5 / 21.0 |
Sawa ya Kupoteza (dB) | 0.4 | 0.6 | 0.8 | 1.2 | 1.5 | 2.0 |
Rudisha Hasara (dB) (Daraja la P / S) | 55/50 | 55/50 | 55/50 | 55/50 | 55/50 | 55/50 |
Upotezaji wa Utegemezi wa ubaguzi (dB) | 0.2 | 0.2 | 0.2 | 0.25 | 0.3 | 0.35 |
Uelekezaji (dB) | 55 | 55 | 55 | 55 | 55 | 55 |
Kupoteza kwa Wategemezi wa Wavelength (dB) | 0.3 | 0.3 | 0.3 | 0.5 | 0.5 | 0.5 |
Utulivu wa Joto (-40 ~ 85 ℃) (dB) | 0.4 | 0.4 | 0.4 | 0.5 | 0.5 | 0.5 |
Joto la Uendeshaji (℃) | -40 ~ 85 | |||||
Joto la Uhifadhi (℃) | -40 ~ 85 | |||||
Kifurushi | Chuma Tube au ABS |
Jedwali 2 - 2 × N PLC Splitter ya nyuzi
Vigezo | 2 × 2 | 2 × 4 | 2 × 8 | 2 × 16 | 2 × 32 | 2 × 64 |
Uendeshaji wa Wavelength (nm) | 1260 hadi 1650 | |||||
Aina ya nyuzi | G657A au mteja ameainishwa | |||||
Kupoteza Uingizaji (dB) | 4.0 | 7.6 | 11.0 | 14.4 | 17.5 | 21.0 |
Sawa ya Kupoteza (dB) | 0.6 | 1.0 | 1.2 | 1.5 | 1.8 | 2.2 |
Rudisha Hasara (dB) (Daraja la P / S) | 55/50 | 55/50 | 55/50 | 55/50 | 55/50 | 55/50 |
Upotezaji wa Utegemezi wa ubaguzi (dB) | 0.2 | 0.2 | 0.3 | 0.3 | 0.4 | 0.4 |
Uelekezaji (dB) | 55 | 55 | 55 | 55 | 55 | 55 |
Kupoteza kwa Wategemezi wa Wavelength (dB) | 0.3 | 0.4 | 0.5 | 0.5 | 0.5 | 0.5 |
Utulivu wa Joto (-40 ~ 85 ℃) (dB) | 0.4 | 0.4 | 0.4 | 0.5 | 0.5 | 0.5 |
Joto la Uendeshaji (℃) | -40 ~ 85 | |||||
Joto la Uhifadhi (℃) | -40 ~ 85 | |||||
Kifurushi | Chuma Tube au ABS |
Vidokezo:
- Iliyoainishwa bila viunganisho.
- Ongeza hasara ya ziada ya 0.15dB kwa kontakt